3,759 research outputs found

    Comparison of Adaptive Optics Scanning Light Ophthalmoscopic Fluorescein Angiography and Offset Pinhole Imaging

    Get PDF
    Recent advances to the adaptive optics scanning light ophthalmoscope (AOSLO) have enabled finer in vivo assessment of the human retinal microvasculature. AOSLO confocal reflectance imaging has been coupled with oral fluorescein angiography (FA), enabling simultaneous acquisition of structural and perfusion images. AOSLO offset pinhole (OP) imaging combined with motion contrast post-processing techniques, are able to create a similar set of structural and perfusion images without the use of exogenous contrast agent. In this study, we evaluate the similarities and differences of the structural and perfusion images obtained by either method, in healthy control subjects and in patients with retinal vasculopathy including hypertensive retinopathy, diabetic retinopathy, and retinal vein occlusion. Our results show that AOSLO OP motion contrast provides perfusion maps comparable to those obtained with AOSLO FA, while AOSLO OP reflectance images provide additional information such as vessel wall fine structure not as readily visible in AOSLO confocal reflectance images. AOSLO OP offers a non-invasive alternative to AOSLO FA without the need for any exogenous contrast agent

    Longitudinal imaging of microvascular remodelling in proliferative diabetic retinopathy using adaptive optics scanning light ophthalmoscopy

    Get PDF
    Purpose To characterise longitudinal changes in the retinal microvasculature of type 2 diabetes mellitus (T2DM) as exemplified in a patient with proliferative diabetic retinopathy (PDR) using an adaptive optics scanning light ophthalmoscope (AOSLO). Methods A 35-year-old T2DM patient with PDR treated with scatter pan-retinal photocoagulation at the inferior retina 1 day prior to initial AOSLO imaging along with a 24-year-old healthy control were imaged in this study. AOSLO vascular structural and perfusion maps were acquired at four visits over a 20-week period. Capillary diameter and microaneurysm area changes were measured on the AOSLO structural maps. Imaging repeatability was established using longitudinal imaging of microvasculature in the healthy control. Results Capillary occlusion and recanalisation, capillary dilatation, resolution of local retinal haemorrhage, capillary hairpin formation, capillary bend formation, microaneurysm formation, progression and regression were documented over time in a region 2° superior to the fovea in the PDR patient. An identical microvascular network with same capillary diameter was observed in the control subject over time. Conclusions High-resolution serial AOSLO imaging enables in vivo observation of vasculopathic changes seen in diabetes mellitus. The implications of this methodology are significant, providing the opportunity for studying the dynamics of the pathological process, as well as the possibility of identifying highly sensitive and non-invasive biomarkers of end organ damage and response to treatment

    Secure Full-Duplex Two-Way Relaying for SWIPT

    Get PDF
    This letter studies bi-directional secure information exchange in a simultaneous wireless information and power transfer (SWIPT) system enabled by a full-duplex (FD) multiple-input multiple-output (MIMO) amplify-and-forward (AF) relay. The AF relay injects artificial noise (AN) in order to confuse the eavesdropper. Specifically, we assume a zeroforcing (ZF) solution constraint to eliminate the residual self-interference (RSI). As a consequence, we address the optimal joint design of the ZF matrix and the AN covariance matrix at the relay node as well as the transmit power at the sources. We propose an alternating algorithm utilizing semi-definite programming (SDP) technique and one-dimensional searching to achieve the optimal solution. Simulation results are provided to demonstrate the effectiveness of the proposed algorithm.Comment: Submitted to IEEE Wireless Communications Letter

    Generating folded protein structures with a lattice chain growth algorithm

    Get PDF
    We present a new application of the chain growth algorithm to lattice generation of proteinstructure and thermodynamics. Given the difficulty of ab initioproteinstructure prediction, this approach provides an alternative to current folding algorithms. The chain growth algorithm, unlike Metropolis folding algorithms, generates independent proteinstructures to achieve rapid and efficient exploration of configurational space. It is a modified version of the Rosenbluth algorithm where the chain growth transition probability is a normalized Boltzmann factor; it was previously applied only to simple polymers and protein models with two residue types. The independent protein configurations, generated segment-by-segment on a refined cubic lattice, are based on a single interaction site for each amino acid and a statistical interaction energy derived by Miyazawa and Jernigan. We examine for several proteins the algorithm’s ability to produce nativelike folds and its effectiveness for calculating protein thermodynamics. Thermal transition profiles associated with the internal energy, entropy, and radius of gyration show characteristic folding/unfolding transitions and provide evidence for unfolding via partially unfolded (molten-globule) states. From the configurational ensembles, the proteinstructures with the lowest distance root-mean-square deviations (dRMSD) vary between 2.2 to 3.8 Å, a range comparable to results of an exhaustive enumeration search. Though the ensemble-averaged dRMSD values are about 1.5 to 2 Å larger, the lowest dRMSD structures have similar overall folds to the native proteins. These results demonstrate that the chain growth algorithm is a viable alternative to protein simulations using the whole chain

    Classification of Human Retinal Microaneurysms Using Adaptive Optics Scanning Light Ophthalmoscope Fluorescein Angiography

    Get PDF
    Purpose. Microaneurysms (MAs) are considered a hallmark of retinal vascular disease, yet what little is known about them is mostly based upon histology, not clinical observation. Here, we use the recently developed adaptive optics scanning light ophthalmoscope (AOSLO) fluorescein angiography (FA) to image human MAs in vivo and to expand on previously described MA morphologic classification schemes. Methods. Patients with vascular retinopathies (diabetic, hypertensive, and branch and central retinal vein occlusion) were imaged with reflectance AOSLO and AOSLO FA. Ninety-three MAs, from 14 eyes, were imaged and classified according to appearance into six morphologic groups: focal bulge, saccular, fusiform, mixed, pedunculated, and irregular. The MA perimeter, area, and feret maximum and minimum were correlated to morphology and retinal pathology. Select MAs were imaged longitudinally in two eyes. Results. Adaptive optics scanning light ophthalmoscope fluorescein angiography imaging revealed microscopic features of MAs not appreciated on conventional images. Saccular MAs were most prevalent (47%). No association was found between the type of retinal pathology and MA morphology (P = 0.44). Pedunculated and irregular MAs were among the largest MAs with average areas of 4188 and 4116 μm2, respectively. Focal hypofluorescent regions were noted in 30% of MAs and were more likely to be associated with larger MAs (3086 vs. 1448 μm2, P = 0.0001). Conclusions. Retinal MAs can be classified in vivo into six different morphologic types, according to the geometry of their two-dimensional (2D) en face view. Adaptive optics scanning light ophthalmoscope fluorescein angiography imaging of MAs offers the possibility of studying microvascular change on a histologic scale, which may help our understanding of disease progression and treatment response

    Relations between concurrent hard X-ray sources in solar flares

    Get PDF
    Context: Solar flares release a large fraction of their energy into non-thermal electrons, but it is not clear where and how. Bremsstrahlung X-rays are observed from the corona and chromosphere. Aims: We aim to characterize the acceleration process by the coronal source and its leakage toward the footpoints in the chromosphere. The relations between the sources reflect the geometry and constrict the configuration of the flare. Methods: We studied solar flares of GOES class larger than M1 with three or more hard X-ray sources observed simultaneously in the course of the flare. The events were observed with the X-ray satellite RHESSI from February 2002 until July 2005. We used imaging spectroscopy methods to determine the spectral evolution of each source in each event. The images of all of the five events show two sources visible only at high energies (footpoints) and one source only visible at low energies (coronal or looptop source, in two cases situated over the limb). Results: We find soft-hard-soft behavior in both, coronal source and footpoints. The coronal source is nearly always softer than the footpoints. The footpoint spectra differ significantly only in one event out of five. Conclusions: The observations are consistent with acceleration in the coronal source and an intricate connection between the corona and chromosphere.Comment: accepted for publication in A&A, 11 pages, 9 figure

    Strategies for Searching Video Content with Text Queries or Video Examples

    Full text link
    The large number of user-generated videos uploaded on to the Internet everyday has led to many commercial video search engines, which mainly rely on text metadata for search. However, metadata is often lacking for user-generated videos, thus these videos are unsearchable by current search engines. Therefore, content-based video retrieval (CBVR) tackles this metadata-scarcity problem by directly analyzing the visual and audio streams of each video. CBVR encompasses multiple research topics, including low-level feature design, feature fusion, semantic detector training and video search/reranking. We present novel strategies in these topics to enhance CBVR in both accuracy and speed under different query inputs, including pure textual queries and query by video examples. Our proposed strategies have been incorporated into our submission for the TRECVID 2014 Multimedia Event Detection evaluation, where our system outperformed other submissions in both text queries and video example queries, thus demonstrating the effectiveness of our proposed approaches
    corecore